DTZY876-TU31 3P4W SPLIT STS METER PLUG IN & PLAY COMMUNICATION MODULE

Pluggable communication module(4G/GPRS/RF/PLC).

Consisting of two parts, the MCU(Metering & Control Unit) + CIU( Customer Interface Unit)

Catalogue-TU31.pdf


The DTZY876 is used for a wide range of smart prepaid metering applications. Is split type, consisting of two parts, the MCU(Metering & Control Unit) and CIU( Customer Interface Unit). The CIU is installed within consumer’s home, while MCU is installed in a meter cabinet away from consumers.


  • DLMS/COSEM standard compliant.

  • IEC62056-21 compliant optical port &VTC allowing for easy data interrogation.

  • Operate in both prepayment and postpayment.

  • Measurement of electrical parameters (Active energy, reactive power, current, voltage, maximum demand.)

  • Programmable load limit and low credit warning.

  • Detection and record event such as opening main cover&terminal cover, current reverse, bypass, phases&neutral interchangeable, neutral missing, phase missing, power outage, magnetic disturbance,last gasp.

  • Downlink communication (between MCU and CIU) is RF/PLC, uplink communication 4G/GPRS/RF/PLC.

  • Digits: 6 integers + 2 decimal.

  • With replaceable battery.



ITEMS

PARAMETERS

Nominal voltage (Un)

3X220/380V,3X230/400V

Limited voltage

60%~120%Un

Nominal frequency (Fn )

50/60Hz

Tolerance

5%

Basic current(Ib)

5A

Maximum current(Imax)

100A

Starting current(Ist)

30mA

Active energy constant

1000imp/kWh

Measurement Accuracy

Class1.0

Voltage circuit burden 

<2W  <8VA

Current circuit burden

<1VA

Operation Temperature

-25℃ to+70℃

Storage Temperature

-40℃ to+85℃

Insulation level

4kV rms 1min

Voltage impulse withstand

6kV 1.2/50 μs

Insulation System Classification

Class II

Contact discharge

8kV

Air discharge

15kV

27MHz to 500MHz typical

10V/m

100kHz to 1GHz typical

30V/m

Fast transient burst test

4kV

Meter shell Protection Rate

IP54

Maximum cable size

10 mm

Connection diagram

AABBCCNN/ABCNNCBA