Bottom meter with RF+MBUS,it's two-phase three-wire sts meter.
The DTZY876 is designed specially for Ecuador market. Main cover&terminal cover are made of transparent polycarbonate, resistant to UV rays (IEC 60068-2-5) and flame retardant.
Is split type, consisting of two parts, the MCU(Metering & Control Unit) and CIU( Customer Interface Unit). The CIU is installed within consumer’s home, while MCU is installed in a meter cabinet away from consumers.
20 digit (Standard Transfer Specification) STS encryption.
DLMS / COSEM standards compliant.
Disconnects on main cover&terminal cover open.
Configurable two modes(prepayment and postpayment).
Events record such as opening mail cover&terminal cover, current reverse , overload, overvoltage, overcurrent.
Ultrasonic welding and 2 screws of type unidirecctional on main cover.
Maximum demand and load profile measurement.
12 selfreading.
Communication downlinked( between MCU and CIU) is RF+MBUS.
Digits: 6 integers + 2 decimal.
ITEMS | PARAMETERS |
Nominal voltage (Un) | 2X120/240V,2x127/220V |
Limited voltage | 80%~115%Un |
Nominal frequency (Fn) | 50/60Hz |
Tolerance | 5% |
Basic current(Ib) | 5A |
Maximum current(Imax) | 100A |
Starting current(Ist) | 30mA |
Active energy constant | 1000imp/kWh |
Measurement Accuracy | Cl1.0 for active, cl.2.0 for reactive |
Voltage circuit burden | <1W |
Current circuit burden | <0.5VA |
Operation Temperature | -25℃ to+70℃ |
Storage Temperature | -40℃ to+85℃ |
AC tension | 4kV/ rms 1min |
Voltage impulse withstand | 6kV 1.2/50 μs |
Insulation System Classification | Class II |
Contact discharge | 8kV |
Air discharge | 15kV |
Surge inmmunity | 6kV/6kA |
Dimensions | 156*140*57mm |
Fast transient burst test | 4kV |
Meter shell Protection Rate | IP54 |
Tarrif | Simple |
Connection diagram | L1L1L2L2NN |